F6Serious

Hotpoint Refrigerator F6 Error Code

The defrost thermistor is not reading properly, often causing the refrigerator to stay in defrost mode too long and not cool.

Common causes

  • Failed defrost thermistor
  • Wiring issue to thermistor
  • Control board problem

How to fix it

  1. Unplug refrigerator for 30 seconds, then plug back in to reset.
  2. Check if the defrost heater is on (visible glow) and evaporator fan runs after defrost.
  3. If the fridge still not cooling, test the defrost thermistor with a multimeter (should read around 11k ohms at 50°F).
⚠ When to call a pro: If the thermistor reads out of range or steps do not resolve, call a technician as the control board may be faulty.

Part links are affiliate links — as an Amazon Associate we may earn a small commission at no extra cost to you.