E212Warning

Bosch Refrigerator E212 Error Code

The defrost temperature sensor is faulty, risking incomplete defrost cycles.

Common causes

  • Defective defrost thermistor
  • Damaged wiring near evaporator
  • Connector corrosion

How to fix it

  1. Unplug and measure resistance of the defrost sensor (typically 10kΩ at 25°C).
  2. Inspect the sensor wiring harness for breaks.
  3. Clean or reseat the connector.
⚠ When to call a pro: If resistance is out of spec (e.g., short or open), replace the sensor; if code persists, call a technician.

Part links are affiliate links — as an Amazon Associate we may earn a small commission at no extra cost to you.

Always unplug the appliance (and turn off the water for washers/dishwashers) before inspecting. These guides are for information only and are not a substitute for a professional repair.