The thermistor (temperature sensor) is reading out of range.

Common causes

  • Faulty thermistor
  • Loose wiring to thermistor
  • Overheating or short circuit

How to fix it

  1. Unplug dryer and clean lint filter and vent system.
  2. Check thermistor connector for damage or looseness.
  3. Measure resistance; should be around 10k ohms at room temp.
⚠ When to call a pro: If cleaning and checking connections doesn't help, replace thermistor.

Part links are affiliate links — as an Amazon Associate we may earn a small commission at no extra cost to you.